The Leiden Institute of Chemistry wishes to purchase an ICP-MS setup (Inductively Coupled Plasma Mass Spectrometer) for its electrochemistry lab. The primary purpose of this setup is to detect and measure the concentration of ions and nanoparticles within the electrolyte of electrochemical cells very low concentrations (ppt-ppq). This requires unique capabilities and accuracy, that can only be provided by the highly sophisticated and state-of-the art design.
Deadline
De termijn voor de ontvangst van de offertes was 2023-11-27.
De aanbesteding werd gepubliceerd op 2023-09-18.
Object Toepassingsgebied van de aanbesteding
Titel: Inductively Coupled Plasma Mass Spectrometer
Producten/diensten: Massaspectrometers๐ฆ
Producten/diensten: FG11
๐ฆ
Korte beschrijving:
โThe Leiden Institute of Chemistry wishes to purchase an ICP-MS setup (Inductively Coupled Plasma Mass Spectrometer) for its electrochemistry lab. The...โ
Korte beschrijving
The Leiden Institute of Chemistry wishes to purchase an ICP-MS setup (Inductively Coupled Plasma Mass Spectrometer) for its electrochemistry lab. The primary purpose of this setup is to detect and measure the concentration of ions and nanoparticles within the electrolyte of electrochemical cells very low concentrations (ppt-ppq). This requires unique capabilities and accuracy, that can only be provided by the highly sophisticated and state-of-the art design.
Toon meer
Geschatte waarde exclusief BTW: EUR 260 000 ๐ฐ
1๏ธโฃ
Aanvullende producten/diensten: Spectrometers๐ฆ
Aanvullende producten/diensten: FG11
๐ฆ
Plaats van uitvoering: Zuid-Holland๐๏ธ
Hoofdlocatie of plaats van uitvoering: Leiden, The Netherlands
Beschrijving van de aanbesteding:
โThe Leiden Institute of Chemistry wishes to purchase an ICP-MS setup (Inductively Coupled Plasma Mass Spectrometer) for its electrochemistry lab. The...โ
Beschrijving van de aanbesteding
The Leiden Institute of Chemistry wishes to purchase an ICP-MS setup (Inductively Coupled Plasma Mass Spectrometer) for its electrochemistry lab. The primary purpose of this setup is to detect and measure the concentration of ions and nanoparticles within the electrolyte of electrochemical cells very low concentrations (ppt-ppq). This requires unique capabilities and accuracy, that can only be provided by the highly sophisticated and state-of-the art design.
Our ICP-MS instrument is intended to be used in series with an electrochemical flow cell, where it can measure and detect the concentrations of the metal ions being introduced into the electrolyte in real-time. The main application would be to measure very low concentrations of metal ions and nanoparticles that come off of the electrode during corrosion in aqueous electrolytes containing high concentration of salts/acids. For the instrument to produce consistent measurements in terms of both concentration of the investigated species as well as the nano-particle size, it should not only have very low and accurate detection limits (ppt-ppq), but also be able to eliminate interference from undesired species and water vapors as much as possible. In addition, the instrument should be able to deal with the high salt concentrations in the electrolytes with minimal maintenance requirements
In addition to that, the ICPMS setup will assist in a wide range of research areas performed by different research groups in the institute including Bio-organic synthesis to catalysis & surface chemistry and supramolecular & biomaterials chemistry. Keeping that in mind, the instrument to be procured is desired to be not only versatile but also user friendly and requiring minimum maintenance and downtime.
Regarding maintenance, the RF coil that ionizes the sample should be corrosion-resistant design, which is crucial for the strong acids and bases used in our application. Second, the instrument should be actively able to separate the uncharged species from the plasma to reduce interferences, contamination and deposits on sensitive surfaces of the ion optics.
The instrument should also be able to remove interferences with the same mass/charge ratio in the collision reaction cell. The instrument should function very well with pure gases (reducing the interference from undesired ions) as well as inert gases (for the removal of unknown spectral polyatomic interferences) at low gas loads in the collision reaction cell.
The instrument should have detection limits in the ppt-ppq concentration range, which is necessary for our research purposes, despite the high salt load from the background electrolyte in our application.
Toon meer Gunningscriteria
De prijs is niet het enige gunningscriterium en alle criteria worden alleen in de aanbestedingsdocumenten vermeld
Toepassingsgebied van de aanbesteding
Geschatte totale waarde exclusief BTW: EUR 260 000 ๐ฐ
Duur van de opdracht, raamovereenkomst of dynamisch aankoopsysteem
Het onderstaande tijdschema is uitgedrukt in aantal maanden.
Beschrijving
Duur: 3
Aanvullende informatie:
โIn 2022 we published our intention to acquire a Inductively Coupled Plasma Mass Spectrometer by means of a negotiated procedure. Representations were...โ
Aanvullende informatie
In 2022 we published our intention to acquire a Inductively Coupled Plasma Mass Spectrometer by means of a negotiated procedure. Representations were received, so that procedure was stopped.
A previous publication (sent on September 15, 2023) was rejected by the European Union for spurious reasons. This is a repeat publication.
Juridische, economische, financiรซle en technische informatie Economische en financiรซle draagkracht
Selectiecriteria zoals vermeld in de aanbestedingsdocumenten
Technische en professionele bekwaamheid
Selectiecriteria zoals vermeld in de aanbestedingsdocumenten
Procedure Soort procedure
Open procedure
Administratieve informatie
Termijn voor de ontvangst van inschrijvingen of verzoeken tot deelneming: 2023-11-27
12:00 ๐
Talen waarin inschrijvingen of aanvragen tot deelneming kunnen worden ingediend: Engels ๐ฃ๏ธ
Het onderstaande tijdschema is uitgedrukt in aantal maanden.
Minimumtermijn gedurende welke de inschrijver de offerte gestand moet doen: 3
Voorwaarden voor de opening van de offertes: 2025-11-27
12:01 ๐
Voorwaarden voor de opening van de offertes (plaats): Leiden, electronically
Aanvullende informatie Informatie over elektronische workflows
Elektronische facturering wordt aanvaard
Beoordelingsorgaan
Naam: Rechtbank Den Haag
Poststad: Den Haag
Land: Nederland ๐ณ๐ฑ Herzieningsprocedure
Precieze informatie over de termijn(en) voor herzieningsprocedures: Within 20 days of contract-award decision.
Bron: OJS 2023/S 183-570573 (2023-09-18)