The reason for the European tender is the need to update the flow cytometry equipment of the FCF. Part of the current equipment is considerably outdated and, as a consequence, does not attain the performance required today and is at the end of its technical life. The flow cytometers that are procured as part of this public tender concern: (a) 3 standard โฅ20-25-color flow cytometers; including a maintenance agreement that can be extended for at least 10 years, which includes preventive maintenance, corrective maintenance and spare parts; (b) 2 high-end โฅ30-35-color flow cytometers;Including a maintenance agreement that can be extended for at least 10 years, which includes preventive maintenance, corrective maintenance and spare parts.
Deadline
De termijn voor de ontvangst van de offertes was 2019-08-02.
De aanbesteding werd gepubliceerd op 2019-06-21.
Aankondiging van een opdracht (2019-06-21) Object Toepassingsgebied van de aanbesteding
Titel: Cytometers
Referentienummer: L-EU-18-05
Korte beschrijving:
The reason for the European tender is the need to update the flow cytometry equipment of the FCF. Part of the current equipment is considerably outdated and, as a consequence, does not attain the performance required today and is at the end of its technical life. The flow cytometers that are procured as part of this public tender concern:
(a) 3 standard โฅ20-25-color flow cytometers; including a maintenance agreement that can be extended for at least 10 years, which includes preventive maintenance, corrective maintenance and spare parts;
(b) 2 high-end โฅ30-35-color flow cytometers;Including a maintenance agreement that can be extended for at least 10 years, which includes preventive maintenance, corrective maintenance and spare parts.
The reason for the European tender is the need to update the flow cytometry equipment of the FCF. Part of the current equipment is considerably outdated and, as a consequence, does not attain the performance required today and is at the end of its technical life. The flow cytometers that are procured as part of this public tender concern:
(a) 3 standard โฅ20-25-color flow cytometers; including a maintenance agreement that can be extended for at least 10 years, which includes preventive maintenance, corrective maintenance and spare parts;
(b) 2 high-end โฅ30-35-color flow cytometers;Including a maintenance agreement that can be extended for at least 10 years, which includes preventive maintenance, corrective maintenance and spare parts.
Aankondigingsmetadata
Originele taal: Engels ๐ฃ๏ธ
Documenttype: Aankondiging van een opdracht
Aard van de opdracht: Leveringen
Regelgeving: Europese Unie, met GPA-deelname
Gemeenschappelijke woordenlijst overheidsopdrachten (CPV)
Code: Cytometers๐ฆ
Aanvullende CPV-code: Instrumentarium en benodigdheden voor diagnostiek en radiodiagnostiek๐ฆ Plaats van uitvoering
NUTS-regio: Nederland
๐๏ธ
Procedure
Type procedure: Openbare procedure
Type bod: Inschrijving voor alle percelen
Gunningscriteria
Uit economisch oogpunt voordeligste inschrijving
Object Toepassingsgebied van de aanbesteding
Korte beschrijving:
The reason for the European tender is the need to update the flow cytometry equipment of the FCF. Part of the current equipment is considerably outdated and, as a consequence, does not attain the performance required today and is at the end of its technical life. The flow cytometers that are procured as part of this public tender concern:
The reason for the European tender is the need to update the flow cytometry equipment of the FCF. Part of the current equipment is considerably outdated and, as a consequence, does not attain the performance required today and is at the end of its technical life. The flow cytometers that are procured as part of this public tender concern:
(a) 3 standard โฅ20-25-color flow cytometers; including a maintenance agreement that can be extended for at least 10 years, which includes preventive maintenance, corrective maintenance and spare parts;
(b) 2 high-end โฅ30-35-color flow cytometers;Including a maintenance agreement that can be extended for at least 10 years, which includes preventive maintenance, corrective maintenance and spare parts.
To accommodate the need to increase its quantitative and qualitative capacity, the FCF seeks to purchase 3 new standard flow cytometers and 2 new high-end flow cytometers. As the FCF has a large number of users (550+) from many different LUMC departments and university departments, it is important to select instruments that allow efficient deployment and use, are intuitive and easy to handle (user friendly), allow fast and easy switching between many different types of applications, are mutually interchangeable (back-up), and require limited instruction time for both hardware and for software. In addition, the new instruments need to be up-to-date and need to provide advanced cutting-edge features that will put the LUMC in the front of the field. This includes the application of advanced flow cytometry for top-reference patient care, such as immune monitoring as companion diagnostics for guiding novel immunotherapies.
To accommodate the need to increase its quantitative and qualitative capacity, the FCF seeks to purchase 3 new standard flow cytometers and 2 new high-end flow cytometers. As the FCF has a large number of users (550+) from many different LUMC departments and university departments, it is important to select instruments that allow efficient deployment and use, are intuitive and easy to handle (user friendly), allow fast and easy switching between many different types of applications, are mutually interchangeable (back-up), and require limited instruction time for both hardware and for software. In addition, the new instruments need to be up-to-date and need to provide advanced cutting-edge features that will put the LUMC in the front of the field. This includes the application of advanced flow cytometry for top-reference patient care, such as immune monitoring as companion diagnostics for guiding novel immunotherapies.
As an example, in case of monitoring >250 leukocyte subsets it should be possible to reduce the number of tubes/stainings from 4 to 5 tubes to approximately 2 tubes, with increased accuracy for leukocyte subset definition. Therefore, the new flow cytometers should be able to acquire at least 25 000 cells per second. In addition, they should be able to detect at least 20-25 colors simultaneously (standard flow cytometers), preferably โฅ30-35 colors (high-end flow cytometers).
As an example, in case of monitoring >250 leukocyte subsets it should be possible to reduce the number of tubes/stainings from 4 to 5 tubes to approximately 2 tubes, with increased accuracy for leukocyte subset definition. Therefore, the new flow cytometers should be able to acquire at least 25 000 cells per second. In addition, they should be able to detect at least 20-25 colors simultaneously (standard flow cytometers), preferably โฅ30-35 colors (high-end flow cytometers).
Geschatte waarde exclusief BTW: 1 000 000 EUR ๐ฐ
Duur: 48 maanden
Beschrijving van de verlengingen: 1 x 3 and 3x1.
Procedure
Rechtsgrondslag: 32014L0024
Tijdstip van ontvangst van inschrijvingen: 10:00
Talen waarin inschrijvingen of aanvragen tot deelneming kunnen worden ingediend: Engels ๐ฃ๏ธ
Nederlands ๐ฃ๏ธ
Datum opening inschrijvingen: 2019-08-02 ๐
Tijdstip van opening inschrijvingen: 10:00
Plaats: Leiden