Filter separators
For protection of the compressors at Quarnstedt and metering devices of station Ellund, horizontal gas/liquid filter separators will be installed. According to operator's experience the incoming process gas contains small contents of solids/liquids (<100 l/day). The condensate mainly consists of water saturated glycols, additives from gas production, and small amounts of higher HC condensates.
The intended configuration per project is 2 filter separators with 100 % capacity, though during normal operation all filter separators are on stream. The turndown capability of the filter separators shall be 0 to 100%. The horizontal filter separator shall be a two stage filter. The first stage with a filter/coalescer element and the second stage with a vane package and beneath the separator vessel a โ€“ two chamber - condensate collection vessel with a minimum diameter of DN400.
Scope:
- The horizontal filter separator shall be a two stage filter. The first stage with a filter/coalescer elements and the second stage with a stainless steel vane package and beneath the separator vessel a โ€“ two chamber - condensate collection vessel with a minimum diameter of DN400.
Proven design, state of the art filter sections shall be provided.
- A two chamber liquid collection vessel beneath the main filter separator vessel, integrated into vessel skirts. Both vessel ends equipped with flanged connection and blind flange with davit.
- Quick opening closure with davit for removal of filter lorry. Quick opening closure shall be equipped with pressure safety device and vent pipe.
- Typical appurtenances like lifting lugs, earthing bosses, on the condensate collection vessel optionally insulation clips (for min 100mm insulation), supports, etc.
- Corrosion protection. In-outside: coating according Gasunie standard to be specified in RFQ.
- Design in accordance with AD 2000.
- All welding activities have to follow AD2000 HP.
- All requireed inspections, non destructive testings, certifications, and documentation.
- Delivery DDP construction site.

Deadline
De termijn voor de ontvangst van de offertes was 2013-03-21. De aanbesteding werd gepubliceerd op 2013-02-18.

Leveranciers
De volgende leveranciers worden genoemd in gunningsbesluiten of andere aanbestedingsdocumenten:
Wie?

Wat?

Waar?
  • โ€ข Deutschland

Aankoopgeschiedenis
Datum Document
2013-02-18 Aankondiging van een opdracht
2014-01-07 Award Aankondiging